Comparing the Effect of Two Portable Cooling Vests on Physiological Parameters under Hot Laboratory Conditions

Firouz valipour, Habibollah Dehghan, Saeed Yazdani Rad, Mansour Zare

Abstract


Personal protective clothing (PPC) can cause heat strain. The purpose of this study was Heat strain control by two portable cooling vests under wearing vapor protective suit and hot condition. An experimental study was conducted in a climatic chamber on 15 male students under warm conditions (ambient temperature =40°C, relative humidity=40%). Each participant performed the test without a cooling vest and with Spadana (Of 70% cotton and 30% polyester with 10 pockets for PCM: Hydrogel packages and a total weight of 2.3kg) and Techkewl-7026 (100% cotton with 4 pockets for PCM packages and a total weight of 2 / 2kg) phase change material cooling vests. The activity rate on a treadmill was light (2.8km/h) and the test lasted 30 minutes for each stage. Cooling effects were evaluated by measuring heart rate, oral temperature and skin temperature. Results showed that the mean and standard deviation for heart rate, oral temperature and skin temperature with a Spadana cooling vest were 100.55 (8.12)(bpm), 36.83 (0.25)°C and 31.52(1.85)°C, respectively, and for Techkewl-7026 cooling vests were 103.64 (10.9)(bpm), 36.98(0.34)°C and 34.2 (1.4)°C, respectively, and for without cooling vest were 113.33(11.23)(bpm), 37.05(0.35) °C and 37.93(0.48) °C, respectively . The difference between parameters with cooling vests and without cooling vest was statistically significant (p < 0.05). The use of Spadana and Techkewl-7026 phase change material cooling vests can reduce thermal stress through a reduction in heart rate, oral temperature, skin temperature and sweating rate.

Keywords


Cooling Vest, Phase Change Materials, Heat Strain, Hot and Dry Conditions

Full Text:

XML PDF

References


Mohammadyan M, Sepehri P. Design of cool spot and assessment of its effect on WBGT index among furnace workers’ position in Shimi Madani industry in Hamadan. Journal of Mazandaran University of Medical Sciences. 2010;20(76):2-7.

Dehghan H, Mortazavi SB, Jafari MJ, Maracy MR. Combination of wet bulb globe temperature and heart rate in hot climatic conditions: The practical guidance for a better estimation of the heat strain. International Journal of Environmental Health Engineering. 2012;1(2):18-23.

Jalil M, Sani MA, Dor Z, Yahya MS, Mohideen Batcha MF, Hasnan K. Heat stress investigation on laundry workers. International Conference on Ergonomics 2007 (ICE07); December 3 - 5 December; Kuala Lumpur, Malaysian, 2007.

Hygienists ACoGI, editor Threshold limit values for chemical substances and physical agents and biological exposure indices 1995: American Conference of Governmental Industrial Hygienists.

Holmér I, Kuklane K, Gao C. Test of firefighter’s turnout gear in hot and humid air exposure. International journal of occupational safety and ergonomics. 2006;12(3):297-05.

Moran DS, Epstein Y. Evaluation of the environmental stress index (ESI) for hot/dry and hot/wet climates. Industrial health. 2006;44(3):399-03.

Wan M. Occupational exposure to hot environments: Florida workers need help. Florida Public Health Review. 2004;1:53-55.

Kjellstrom T, Holmer I, Lemke B. Workplace heat stress, health and productivity “an increasing challenge for low and middle-income countries during climate change. Global Health Action. 2009;2(1):20-47.

Morabito M, Cecchi L, Crisci A, Modesti PA, Orlandini S. Relationship between work-related accidents and hot weather conditions in Tuscany (central Italy). Industrial health. 2006;44(3):458-64.

Tamas R. Review Article: Heat stress and the role of protective clothing in military service. Journal of College of Medicine. 2011;14(2):82-84

Adams PS, Slocum AC, Monroe Keyserling W. A model for protective clothing effects on performance. International Journal of Clothing Science and Technology. 1994;6(4):6-16.

Havenith G. Heat balance when wearing protective clothing. Annals of Occupational Hygiene. 1999;43(5):289-96.

Cheung SS, McLellan TM, Tenaglia S. The thermophysiology of uncompensable heat stress. Sports Medicine. 2000;29(5):329-59.

Borg DN, Stewart IB, Costello JT. Can perceptual indices estimate physiological strain across a range of environments and metabolic workloads when wearing explosive ordnance disposal and chemical protective clothing? Physiology & behavior. 2015;147:71-77.

Carter III R, Cheuvront SN, Williams JO, Kolka MA, Stephenson LA, Sawka MN, et al. Epidemiology of hospitalizations and deaths from heat illness in soldiers. Med Sci Sports Exerc. , 2005; 37(8):1338-44.

Center AFHS. Update: Heat injuries, active component, US Armed Forces, 2013. Msmr. 2014;21(3):10-13.

Nishihara N, Tanabe S-i, Hayama H, Komatsu M. A cooling vest for working comfortably in a moderately hot environment. Journal of physiological anthropology and applied human science. 2002;21(1):75-82.

Jetté F-X, Dionne J-P, Rose J, Makris A. Effect of thermal manikin surface temperature on the performance of personal cooling systems. European journal of applied physiology. 2004;92(6):669-72.

Reinertsen RE, Færevik H, Holbø K, Nesbakken R, Reitan J, Røyset A, et al. Optimizing the performance of phase-change materials in personal protective clothing systems. International Journal of Occupational Safety and Ergonomics. 2008;14(1):43-53.

Bendkowska W, Kłonowska M, Kopias K, Bogdan A. Thermal Manikin evaluation of PCM cooling vests. Fibres & Textiles in Eastern Europe. 2010;18(1):70-74.

Bennett BL, Hagan RD, Huey K, Minson C, Cain D. Comparison of two cool vests on heat-strain reduction while wearing a firefighting ensemble. European journal of applied physiology and occupational physiology. 1995;70(4):322-28.

Jovanovic DB, Karkalić R, Tomić L, Veličković Z, Radaković S. Efficacy of a novel phase change material for microclimate body cooling. Therm Sci. 2014;18:657-65.

Jovanovic D, Karkalic R, Radakovic S. Physiological tolerance to uncompensated heat stress in soldiers: effects of various types of body cooling systems. Vojnosanitetski pregled. 2014;71(3):259-64.

Chou C, Tochihara Y, Kim T. Physiological and subjective responses to cooling devices on firefighting protective clothing. European journal of applied physiology. 2008;104(2):369-74

Yazdanirad S, Dehghan H. Designing of the cooling vest from paraffin compounds and evaluation of its impact under laboratory hot conditions. International journal of preventive medicine. 2016; 7(1):47

Dehghan H, Gharehbaei S, Mahaki B. Performance evaluation of Iranian cooling vest on the physiological indices in hot climatic chamber. Journal of Education and Health Promotion. 2016;5:15




Iranian Journal of Health, Safety and Environment e-ISSN: :2345-5535 Iran university of Medical sciences, Tehran, Iran